iRAYPLE R5050PMG-05M — R5000 Series fixed-mount code reader; 5 MP (2592 × 1944) at 50 fps; 5 mm auto-focus lens; read distance 25–2000 mm; min. code 1D code 0.02 mm / 2D code 0.037 mm; integrated red/white illumination; Ethernet, RS-232, PROFINET, EtherNet/IP, Digital I/O; IP67.
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
Scan technology
2D area imager (global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR/PDF417 etc.
The 5 mm lens on a 5 MP sensor (2592 × 1944 px) frames 32 × 24 mm at the 25 mm near limit and 2157 × 1617 mm at 2000 mm. A pixel covers 32 ÷ 2592 ≈ 0.0123 mm near the lens and 2157 ÷ 2592 ≈ 0.83 mm at the far limit, essentially the same as on the 1.6 MP R5016PMG-05M. The 2D minimum module is therefore the same 0.037 mm, and the gain is coverage: 32 mm of near-field width against 17 mm.
Frame rate falls to 50 fps and decoding to 100 codes/s (R5016PMG-05M: 120 codes/s). At the 3 m/s maximum object speed a code crosses the 32 mm near field in 32 ÷ 3000 s ≈ 10.7 ms, shorter than the 20 ms frame period, so close-range reads need a trigger timed to the part. Built-in deep-learning decoding runs in an IP67 body.
Best for
One reader covering a large scene at 1.5–2 m, for example a 2157 × 1617 mm area at 2000 mm where code positions vary widely.
Close reads at 25 mm through a 32 × 24 mm window, for installations that cannot place the code precisely.
Large printed labels on containers and stacked goods, where modules of 2.5 mm or more (3 px × 0.83 mm) are needed at 2 m.
Selection notes
If you need 60 fps and 120 codes/s, R5016PMG-05M offers both with a narrower field.
For smaller marks choose a 12 mm unit such as R5050PMG-12M (21 × 16 mm at 50 mm, 0.014 / 0.026 mm minimums).
At 2 m the integrated light has to cover a field of about 2 m, and illumination typically falls off quickly with distance, so test your labels at the far end.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in deep-learning algorithms and multi-parameters polling to ensure effects of complex applications
Specifications: Sensor
Resolution
5 MP (2592 × 1944)
Horizontal resolution
2592 px
Specifications: Performance
FPS
50 fps
Specifications: Interface
Communication
100M Ethernet; protocols: SDK,TCP Client,TCP Server,FTP,RS232,Profinet,Modbus,EtherNet/IP,MC(SLMP),FINS/UDP,FINS/TCP
Connection
2 Industrial M12 connectors support GigE and GPIO
Specifications: Optical
Field of view
32 mm × 24 mm – 2157 mm × 1617 mm
Focal length
5 mm
Focus
Motorised auto focus (M10 lens)
Integrated lighting
Red, Polarized/Non-polarized; White,diffuse light · White, Polarized/Non-polarized/diffuse light — depending on order code
Illumination colour
Red, Polarized/Non-polarized; White,diffuse light · White, Polarized/Non-polarized/diffuse light — depending on order code
Specifications: Electrical
Supply voltage
16–26V DC, 1A input
Power consumption
<6 W(light included)
Specifications: Environment
IP rating
IP67
Operating temperature
-20 °C to +50 °C
Specifications: Reading
Scan technology
2D area imager (global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR/PDF417 etc.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Integrated lighting ●
Illumination colour ●
Availability
red/white light Base
Red, Polarized/Non-polarized; White,diffuse light
Red, Polarized/Non-polarized; White,diffuse light
On request
white light
White, Polarized/Non-polarized/diffuse light
White, Polarized/Non-polarized/diffuse light
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
About 1.9 times at the near limit (32 mm against 17 mm) and 1.8 times at 2000 mm (2157 mm against 1198 mm), at about the same pixel size on the part.
Yes. PDF417 is among the supported 2D symbologies, together with Data Matrix, Micro QR, GS1 DataMatrix and GS1 QR.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE