iRAYPLE R5050PMG-12L — R5000 Series fixed-mount code reader; 5 MP (2592 × 1944) at 50 fps; 12 mm liquid lens; read distance 90–2000 mm; min. code 1D code 0.028 mm / 2D code 0.059 mm; integrated red/white illumination; Ethernet, RS-232, PROFINET, EtherNet/IP, Digital I/O; IP67.
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
Scan technology
2D area imager (global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR/PDF417 etc.
A liquid lens with ToF-assisted focusing on a 5 MP sensor (2592 × 1944 px) gives 43 × 32 mm at 90 mm and 880 × 660 mm at 2000 mm. A pixel near the lens covers 43 ÷ 2592 ≈ 0.0166 mm, matching the 1.6 MP and 3.1 MP versions, so the 0.059 mm 2D minimum is still about 3.6 px at the near limit. What 5 MP buys is a window about 1.8 times as wide as R5016PMG-12L's 24 mm.
ToF assistance lets boxes of different heights come into focus as they arrive, with a measured distance guiding the lens instead of a per-product setting. The unit decodes up to 120 codes/s at 50 fps and has built-in AI decoding. The operating range is 0 to +45 °C, against −20 to +50 °C on R5050PMG-12M.
Best for
Mixed-height boxes or totes on one line, where ToF-assisted focus follows the distance and fields from 43 × 32 mm to 880 × 660 mm keep the code in view.
Sorting points that need one fixed reader for tall and short items, because focus follows the item instead of being set per product.
Stations that need positional tolerance near the reader: the 43 × 32 mm window at 90 mm is about 3.2 times the area of R5016PMG-12L's 24 × 18 mm.
Selection notes
If your marks need 0.026 mm 2D modules, use R5050PMG-12M (motorised, from 50 mm); this model's minimum is 0.059 mm.
Allow for heat from drives and power supplies near the reader: the operating range stops at +45 °C, and below 0 °C the reader is outside it.
At 50 fps a 3 m/s part moves 3000 ÷ 50 = 60 mm per frame, so a 43 mm window at 90 mm needs a trigger tied to part position. Confirm the light variant when ordering.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in deep-learning algorithms and multi-parameters polling to ensure effects of complex applications
Specifications: Sensor
Resolution
5 MP (2592 × 1944)
Horizontal resolution
2592 px
Specifications: Performance
FPS
50 fps
Specifications: Interface
Communication
100M Ethernet; protocols: SDK,TCP Client,TCP Server,FTP,RS232,Profinet,Modbus,EtherNet/IP,MC(SLMP),FINS/UDP,FINS/TCP
Connection
2 Industrial M12 connectors support GigE and GPIO
Specifications: Optical
Field of view
43 mm × 32 mm – 880 mm × 660 mm
Focal length
12 mm
Focus
Liquid lens (auto focus) with ToF-assisted real-time focusing
Integrated lighting
Red, Polarized/Non-polarized; White,diffuse light · White, Polarized/Non-polarized/diffuse light — depending on order code
Illumination colour
Red, Polarized/Non-polarized; White,diffuse light · White, Polarized/Non-polarized/diffuse light — depending on order code
Specifications: Electrical
Supply voltage
16–26V DC, 1A input
Power consumption
<6 W(light included)
Specifications: Environment
IP rating
IP67
Operating temperature
0 °C to +45 °C
Specifications: Reading
Scan technology
2D area imager (global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR/PDF417 etc.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Integrated lighting ●
Illumination colour ●
Availability
red/white light Base
Red, Polarized/Non-polarized; White,diffuse light
Red, Polarized/Non-polarized; White,diffuse light
On request
white light
White, Polarized/Non-polarized/diffuse light
White, Polarized/Non-polarized/diffuse light
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
Changing code height. The liquid lens with ToF-assisted focus follows distance from 90 to 2000 mm, whereas the motorised lens suits fixed-height work with finer minimum modules.
With the EasyID software. A green light shows the read result.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE