Two numbers define this model: 640 × 512 px and a focus fixed at 110 mm. At that distance the 81 × 65 mm field gives 81 mm ÷ 640 px ≈ 0.127 mm per pixel, so the minimum modules of 0.14 mm (1D) and 0.32 mm (2D) correspond to about 1.1 px and 2.5 px. Treat those as best cases: for dependable reads use 2D modules of about 0.4 mm or more, which gives roughly 3 px (0.4 ÷ 0.127 ≈ 3.2). Decoding reaches 42 codes/s, against 31 codes/s on the 1.3 MP R3013MG/U-05-DEE110E at the same 110 mm focus.
The global-shutter imager runs at 60 fps with software, external or free-run triggering, and a red/white dual light is built in. The body is 50 × 50 × 28.5 mm and under 130 g, and an M12 connector carries 100M Ethernet with PROFINET, EtherNet/IP, Modbus, MELSEC and FINS.
Best for
Stations with a fixed stand-off, such as a guide rail or jig, where every code passes 110 mm from the lens and nobody wants to refocus.
Labels with large 2D modules (about 0.4 mm and up), where 640 × 512 px already gives about 3 px per module.
PLC cells that want results on PROFINET or EtherNet/IP over an M12 Ethernet port, from a body of only 50 × 50 × 28.5 mm.
Selection notes
Focus is fixed, so the mounting height sets the result: measure how far your parts vary from 110 mm before relying on any depth of field.
Smaller modules need more pixels: the R3013MG/U-05-DEE110E has the same 81 × 65 mm field on 1280 × 1024 px with a 0.16 mm 2D minimum, and the R3004MG-05H adds manual focus over 40–150 mm.
For a dusty or wet station choose a sealed model: the R3016PMG-07H is rated IP65. Confirm the sealing of this housing before mounting it in such a place.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
It has fixed focus at 110 mm, where the field of view is 81 × 65 mm.
DPM is among its supported code types, but with 640 × 512 px and a 0.32 mm 2D minimum, fine marks are a poor fit. For those, choose a 1.3 MP or higher model and test on real parts.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE