Manual focus lets one 0.33 MP body cover 40–150 mm, with a field that grows from 31 × 24 mm to 110 × 88 mm. Resolution per pixel changes across that range: 31 mm ÷ 640 px ≈ 0.048 mm at 40 mm and 110 mm ÷ 640 px ≈ 0.172 mm at 150 mm. The minimum modules of 0.06 mm (1D) and 0.13 mm (2D) can therefore be approached only near the 40 mm end, where they work out to about 1.2 px and 2.7 px; decoders typically want about 2 px per module, so the 1D figure is a best case, and at 150 mm 2 px means about 0.34 mm (2 × 0.172 mm).
Two order codes change lighting and size: a red/white dual light (under 2.5 W, 50 mm long) and white only (under 4.5 W, 52 mm long, field 32 × 26 to 112 × 89 mm). The housing is IP40, which keeps out solids larger than about 1 mm but gives no protection against water, so plan a cover or enclosure on dusty or wet lines.
Best for
Stations where the stand-off changes between product types, since focus is set by hand anywhere in 40–150 mm.
Close-up reading of small labels near the 40 mm end, where one pixel covers about 0.048 mm and the 0.13 mm 2D minimum is within reach.
Cells that value a higher decode ceiling than a 1.3 MP reader gives: 42 codes/s, against 31 codes/s on the R3013MG/U-05H.
Selection notes
If the distance never changes, the R3004MG-05-DEE110E has the same 0.33 MP sensor with fixed focus at 110 mm.
The hand-set focus has no motor, so each changeover is a manual step. A cell that moves between distances often suits the motorised autofocus of the R4013MG-07M (50–500 mm).
For finer prints at the same range, the R3013MG/U-05H adds 1280 × 1024 px and a 0.05 mm 1D and 0.08 mm 2D minimum.
Pick the red/white or white-only version by how your label surface responds to light colour; the white-only version has no red light and draws up to 4.5 W.
50 × 50 × 28.5 mm (Without cable) (R3004MG-05H-DEE01E) · 52 × 50 × 28.5 mm (Without cable) (R3004MG-05H-WEE01E)
Weight
<130 g
Housing material
Aluminum alloy + Front cover
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Field of view ●
Integrated lighting ●
Illumination colour ●
Power consumption ●
Dimensions ●
Availability
red/white light Base
31 × 24 mm – 110 × 88 mm
Red/white dual light
Red/white dual light
<2.5 W
50 × 50 × 28.5 mm (Without cable)
On request
white light
32 × 26 mm – 112 × 89 mm
White
White
<4.5 W
52 × 50 × 28.5 mm (Without cable)
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
One has a red/white dual light and draws under 2.5 W in a 50 mm housing. The other has white light only, draws under 4.5 W and is 52 mm long.
DPM is in its supported codes. With a 0.13 mm 2D minimum at the 40 mm end (about 2.7 px), fine direct marks call for a higher-resolution model, and any DPM job should be tested on real parts.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE