iRAYPLE R3138MG011E — AGV / AMR Data Matrix positioning code reader; 3 mm fixed-focus lens; read distance 100 mm ± 20 mm (depth of field); integrated white illumination; Ethernet, RS-485, Digital I/O; IP65.
The R3138MG011E trades magnification for sideways tolerance: its 3 mm lens gives a 132 × 110 mm field at the same 100 mm ± 20 mm stand-off, about 20 % wider and 18 % taller than the 110 × 93 mm of the R3138MG010E (132 ÷ 110 = 1.2; 110 ÷ 93 ≈ 1.18). A wider field lets a vehicle stray further from its line of markers before losing one, and keeps a marker in view for more frames: at the 3 m/s maximum object speed and 120 fps (25 mm of travel per frame) a point stays visible for 132 ÷ 25 ≈ 5.3 frames.
The cost is detail per pixel, because each pixel now sees more of the surface. Positioning accuracy is 0.1 mm and 0.1°, the same as on the R3138MG010E, and only DM-12, DM-14 and DM4x4 formats are decoded. The supply is 24 VDC ±10 %, which on a battery-fed vehicle bus means watching the voltage swing during charging. A global-shutter imager and a white LED are built in, and the housing is IP65 aluminium alloy.
Best for
AGVs that wander laterally on their route, where the wider field keeps markers in view.
Faster vehicles, since a 132 mm field gives more frames per marker at 3 m/s and 120 fps.
Vehicles whose ride height varies, where the 80–120 mm stand-off window plus a wide field absorb the variation.
Selection notes
If marker detail is the limit rather than coverage, the R3138MG010E (110 × 93 mm, 3.37 mm lens) covers less area, so a marker fills more of the image.
For general barcode reading, use a reader from the R3000 or R4000 families; this one decodes the DM-12, DM-14 and DM4x4 positioning formats.
Triggering is by single frame, software command or free run, and the software is SVStudio.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
Specifications: Performance
FPS
120 fps
Specifications: Interface
Communication
100M Ethernet; protocols: SDK, Serial, TCP Server, TCP Client
Connection
1 × M12 connector
Specifications: Optical
Field of view
132 mm × 110 mm
Focal length
3 mm
Focus
Fixed focus (Stationary type)
Integrated lighting
White LED
Illumination colour
White LED
Specifications: Electrical
Supply voltage
DC24V±10%
Power consumption
illumination off: <3.5 W@24VDC; illumination on: <7.5 W@24VDC
Specifications: Environment
IP rating
IP65
Operating temperature
-20 °C to +50 °C
Specifications: Reading
Scan technology
2D area imager (global shutter)
Supported codes
DM-12&DM-14, DM4x4
Read distance
100 mm ± 20 mm (depth of field)
Specifications: Mechanical
Dimensions
60 × 60 × 43 mm (excluding interface port)
Weight
<225 g
Housing material
Aluminum alloy
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
132 mm × 110 mm at 100 mm, with a ±20 mm depth of field.
One opto-isolated input and one opto-isolated output are available, typically used for an external trigger and a result signal.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE