The 12 mm lens sits between the 8 mm and 16 mm R5050MG models: 134 × 101 mm at 200 mm, against 216 × 164 mm and 99 × 75 mm. A pixel on the part at 200 mm covers 134 mm ÷ 2368 px ≈ 0.057 mm, so the rated 0.06 mm 2D minimum is about 1 px there and belongs to the near end: at 80 mm, scaling the field roughly with distance, a pixel is about 0.023 mm and a 0.06 mm module spans about 2.7 px.
To size a job, use about 3 px per module as a rule of thumb: at 200 mm this lens holds 0.17 mm modules (3 × 0.057 mm). Scaled with distance, 0.1 mm modules hold 3 px only to about 117 mm, 0.25 mm modules to about 290 mm and 0.5 mm modules to about 585 mm. Decoding is AI-assisted (deep learning with multi-parameter polling), the red or white light is integrated, and the body is IP65.
Best for
Mixed work in one cell, such as 0.2 mm codes near 150 mm and 0.5 mm labels near 500 mm, where motorised auto focus lets one reader cover both: with the field scaled with distance, a pixel is about 0.042 mm at 150 mm and 0.14 mm at 500 mm, giving about 4.7 px and 3.5 px per module.
Cells where one code may sit anywhere in a 134 × 101 mm area, for instance on hand-placed parts.
Replacing a 16 mm unit when code placement scatters: the field is about 1.8 times the area of R5050MG-16M's 99 × 75 mm.
Selection notes
If your marks are around 0.1 mm, R5050MG-16M (0.042 mm per pixel at 200 mm, 99 ÷ 2368) gives more margin than this lens.
If codes are 0.5 mm or larger and you want a wider field, R5050MG-08M offers 216 × 164 mm at 200 mm.
Pick red or white integrated light by order code, and test both on your lowest-contrast part before fixing the choice.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in deep-learning algorithms and multi-parameters polling to ensure effects of complex applications
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Integrated lighting ●
Illumination colour ●
Availability
red light Base
Red
Red
On request
white light
White
White
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
Scaling the 134 × 101 mm field at 200 mm in proportion to distance (an estimate) gives about 54 × 40 mm at 80 mm and about 1005 × 758 mm at 1500 mm.
PROFINET, EtherNet/IP, Modbus, MC (SLMP) and FINS, plus TCP client and server, FTP and an SDK, over a GigE port.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE