This reader has the same 16 mm focal length as R5016MG-16M on a bigger sensor: 4.2 MP (2368 × 1792 px) frames 99 × 75 mm at 200 mm against 61 × 46 mm. The pixel on the part is practically unchanged (99 mm ÷ 2368 px ≈ 0.042 mm), so the extra pixels buy field area, about 2.6 times as much (7425 mm² against 2806 mm²), not finer detail.
Read range starts at 100 mm, 20 mm later than on the 8 and 12 mm R5050MG models. At 100 mm a pixel is about 0.021 mm (field scaled roughly with distance), so the 0.04 mm minimum module covers about 1.9 px: usable, with little margin, so mark contrast and focus must be good. Frame rate is 45 fps against 60 fps on R5016MG-16M. Decoding is AI-assisted (deep learning with multi-parameter polling), and the red or white light is integrated.
Best for
Small 2D marks that are not always in the same place, where a 99 × 75 mm field absorbs scatter that would push a code out of a 61 × 46 mm field.
Codes at 100–300 mm: a pixel on the part runs from about 0.021 mm at 100 mm to 0.063 mm at 300 mm (field scaled with distance: 99 × 300/200 = 148.5 mm ÷ 2368 px), so a 0.2 mm module still gets about 3 px at 300 mm.
Fixtures where part height varies between products: motorised auto focus covers the whole 100–1500 mm range without a manual refocus.
Selection notes
At the rated 3 m/s and 45 fps a part moves about 67 mm per frame, two-thirds of the 99 mm field, so a code is in view for only one or two frames. An external trigger timed to the part is the safer choice than free run.
If you need 60 fps, R5016MG-16M offers it with the narrower 61 × 46 mm field. If codes are larger than about 0.17 mm, R5050MG-12M offers 134 × 101 mm on the same sensor.
Red or white light is fixed by the order code, so confirm it against your label colours before ordering.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in deep-learning algorithms and multi-parameters polling to ensure effects of complex applications
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Integrated lighting ●
Illumination colour ●
Availability
red light Base
Red
Red
On request
white light
White
White
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
Common 1D codes (Code 39, Code 93, Code 128, Codabar, EAN, UPC, ITF-25, 2 of 5 and GS1-128) and 2D Data Matrix, Micro QR, GS1 DataMatrix and GS1 QR.
The decoder is rated at 90 codes/s while frames run at 45 fps, so with one code per trigger the frame rate is the limit; the decode rate matters when a frame holds several codes.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE