The 8 mm lens gives a wider view than the 12 mm (134 × 101 mm) and 16 mm (99 × 75 mm) R5050MG models: 216 × 164 mm at 200 mm. On the 4.2 MP sensor (2368 × 1792 px) one pixel covers 216 mm ÷ 2368 ≈ 0.091 mm, so at 200 mm a 2D module needs about 0.27 mm for 3 px. The rated 0.09 mm 2D minimum is about 1 px there, so it is a near-end figure: at 80 mm, with the field scaled roughly with distance, a pixel is about 0.036 mm (216 × 80/200 ≈ 86 mm ÷ 2368 px) and a 0.09 mm module spans about 2.5 px.
A wide field forgives timing: at the rated 3 m/s and 45 fps a part advances about 67 mm per frame (3000 ÷ 45), so a code a few centimetres wide is fully in view for two to three frames. AI decoding is built in (deep learning with multi-parameter polling), the red or white light is integrated, and the body is IP65.
Best for
Several labels or marks in one frame, such as carton faces, trays or layered pallets, inside a 216 × 164 mm field at 200 mm.
Lanes where the code position wanders by tens of millimetres: the wide field absorbs scatter that narrower lenses would cut off.
Shipping and part-identification labels with large modules, about 0.3 mm and up at 200 mm (3 px × 0.091 mm).
Selection notes
The wide view costs pixel size: at 200 mm R5050MG-12M gives 0.057 mm per pixel (134 ÷ 2368) and R5050MG-16M 0.042 mm (99 ÷ 2368), against 0.091 mm here.
Integrated light typically falls off roughly with the square of distance, so test the far end of the read range with your real labels before relying on 1500 mm.
For 60 fps, R5016MG-16M offers it with a 61 × 46 mm field, against 45 fps here, and adds polarized light options; this model's choice is red or white.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in deep-learning algorithms and multi-parameters polling to ensure effects of complex applications
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Integrated lighting ●
Illumination colour ●
Availability
red light Base
Red
Red
On request
white light
White
White
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
No. Scaled to 1500 mm the field is about 1.6 m wide (216 × 1500/200 = 1620 mm), roughly 0.68 mm per pixel (1620 ÷ 2368), so even a 3 px read needs modules near 2 mm. Use the far range for large labels only.
9–26 V DC at 2 A, so 12 V and 24 V rails both work.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE