Rolling shutter is the trade for the extra width. This Windows 10 smart camera gives 3072 × 2048 px (6.3 MP, 3:2) from 2.4 µm pixels on a 1/1.8-inch sensor at 30 fps, but rows are exposed one after another, so a part that moves during readout looks skewed. Next to DH-MV-SI5500MG002E (global shutter, 2448 px, 3.45 µm) it pays off on stopped or slow parts: an example 100 mm field gives 100 mm ÷ 3072 ≈ 33 µm per pixel against 100 mm ÷ 2448 ≈ 41 µm. The MVP platform or your own SDK application runs on the camera's x86 platform and only results leave over Ethernet.
Smaller pixels ask more of optics and light. The active area is 7.4 mm × 4.9 mm (3072 × 2.4 µm by 2048 × 2.4 µm), a diagonal of about 8.9 mm, and the 2.4 µm pitch means a Nyquist limit of 1 ÷ (2 × 2.4 µm) ≈ 208 lp/mm. Each pixel has about half the area of a 3.45 µm one ((2.4 ÷ 3.45)² ≈ 0.48), so expect to give back exposure time or light. A strobe freezes motion only if the flash falls in the interval when every row is exposing, which calls for a long exposure with ambient light excluded; a global-shutter camera has no such constraint.
Best for
Measurement of parts that stop in a fixture, where 3072 px across samples more finely than the 2448 px of the 5 MP models.
Surface and defect checks on indexed or slow-moving parts under steady light, where rolling-shutter skew stays below the tolerance.
Parts wider than they are tall, since the 3:2 frame of 3072 × 2048 px fits them better than the roughly 6:5 frame (2448 × 2048 px) of DH-MV-SI5500MG002E.
Selection notes
Fast conveyors call for a global shutter: DH-MV-SI5500MG002E (5 MP, 35 fps) and SI5501CG002E (5 MP colour) have one.
The C-mount lens (not included) must cover about 9 mm of image circle. Look for lenses specified for pixels of 2.4 µm or smaller, because a lens made for larger pixels leaves sharpness unused.
The 12-pin connector offers three inputs and three outputs without opto-isolation, and a capture can start from software, a hardware trigger or free run.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
No, it uses a rolling shutter. The 5 MP DH-MV-SI5500MG002E at 35 fps is the global-shutter alternative for moving parts.
Over the Gigabit Ethernet port by PROFINET, Modbus TCP, TCP server or TCP client, or over RS-232 or RS-485. The 12-pin connector adds three inputs and three outputs for hardware handshakes.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE