The AH5049CU000E is a color 0.4 MP camera with an HR sensor in a 1/2.9-inch CMOS format, delivering 720 x 540 px at 6.9 µm pixel pitch with a global shutter and a USB 3.0 interface. Its listed rate is 525 fps at 720 x 540 px in Bayer RG 8, a figure that applies to this small frame and pixel format. That makes it suited to high-speed inspection of small fields of view rather than high-resolution imaging. Confirm how color is reconstructed from the Bayer RG 8 output in your software before building the processing chain.
The 6.9 µm pixel pitch is large, and larger pixels generally collect more light per pixel, which helps when exposure times are very short. Power can come from the USB connector or from DC 9 V to 24 V through a Hirose connector, at 2.6 W. The body is 29 x 29 x 30 mm and weighs 85 g, a compact package for a USB 3.0 camera. The C-mount accepts standard lenses, and the resolution demands are modest at 720 x 540 px.
Expect very short exposures at 525 fps, so plan strong, pulsed illumination synchronized to the exposure, and confirm the achievable rate at your region of interest. The listed operating range of -30 to +50 °C suits installations with wide temperature swings.
Best for
High-speed inspection of small fields of view at 720 x 540 px.
Fast-moving small parts, where short exposures benefit from the 6.9 µm pixel pitch.
Color inspection where 0.4 MP resolution is enough.
Installations on a wide temperature range from -30 to +50 °C.
Selection notes
The 525 fps figure applies at 720 x 540 px in Bayer RG 8; confirm the rate for any other format or region of interest.
Plan pulsed lighting for very short exposures.
Confirm color reconstruction from the Bayer RG 8 output in your software.
Choose a C-mount lens for the 1/2.9-inch format.
Confirm trigger input details in the manufacturer datasheet before finalizing the design.
Specifications: General
Brand
iRAYPLE
Camera type
Area Scan
Specifications: Sensor
Sensor model
HR
Sensor size
1/2.9"CMOS
Shutter
Global
Mono / color
Color
Resolution
0.4 MP
Horizontal resolution
720 × 540 px
Pixel size
6.9 μm × 6.9 μm
Specifications: Performance
FPS
525 fps @720 × 540 Bayer RG 8
Specifications: Interface
Interface
USB 3.0
Specifications: Optics
Mount
C-mount
Specifications: Electrical
Supply voltage
Power supply via USB connector /DC power supply by Hirose connector, with voltage range from 9V to 24V
Power consumption
2.6 W
Specifications: Environment
Operating temperature
-30℃~+50℃
Specifications: Mechanical
Dimensions
29 mm×29 mm×30 mm (not including lens mount and rear case connector)
Weight
85 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
9 frame grabbers / interface cards are compatible with this camera.
Matched automatically by: card supports the camera interface (usb3 vision) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this camera: USB 3.0.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
525 fps at 720 x 540 px in Bayer RG 8.
Yes, the color mode is listed as Color, with Bayer RG 8 output.