The Hikrobot MV-CH120-60NM is a 12 MP monochrome area scan camera built on a Stacked BSI CMOS sensor listed with a 1.1" sensor size and 3.45 μm × 3.45 μm pixels. The frame is 4096 × 3072 px, and the camera is rated at up to 24 fps at that resolution in Mono 8. The CMOS, global shutter exposes the whole frame in one window, so moving parts are captured without rolling-shutter skew. Data runs over 2.5 Gigabit Ethernet (2500 Mbit/s), with compatibility with Gigabit Ethernet (1000 Mbit/s) also listed, and the protocols are GigE Vision V2.0 and GenlCam.
The 24 fps rate on a 12 MP grayscale frame over a 2500 Mbit/s link suits networked inspection that needs full-resolution images at a steady capture rate. Power is 9 VDC to 24 VDC or PoE, and power consumption is 4 W, which belongs in the cabinet power budget. The 100 g body uses a C-mount, so choose a lens whose image circle covers the 1.1" sensor to use the full 4096 × 3072 px frame.
The IP40 rating applies under proper lens installation and wiring, so seat the lens and cable connections correctly. The Mono 8 output is a grayscale image, which suits edge-based measurement, surface checks and presence checks on moving parts. Lens and lighting selection should be driven by the working distance and field of view of the part.
Best for
Grayscale inspection at 12 MP, 4096 × 3072 px, over 2.5 Gigabit Ethernet.
Networked cells that need full-resolution monochrome frames at up to 24 fps.
Edge-based measurement and surface checks that use Mono 8 images.
PoE-powered GigE installations that keep power and data on one network cable.
C-mount optics setups with a 1.1" sensor for full-resolution monochrome capture.
Selection notes
Use network hardware that supports 2.5 Gigabit Ethernet (2500 Mbit/s); the camera is also compatible with Gigabit Ethernet (1000 Mbit/s), at a lower link speed.
Plan the power route: 9 VDC to 24 VDC from a local supply, or PoE, and budget the 4 W draw.
Check the trigger and I/O details in the manufacturer datasheet before wiring strobe lighting or external synchronization.
Choose a C-mount lens whose image circle covers the 1.1" sensor, and seat it correctly since IP40 applies under proper lens installation and wiring.
Confirm the host software supports GigE Vision V2.0 and GenlCam, the protocols listed for this camera.
30 frame grabbers / interface cards are compatible with this camera.
Matched automatically by: card supports the camera interface (gige vision) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this camera: 2.5 Gigabit Ethernet (2500 Mbit/s), compatible with Gigabit Ethernet (1000 Mbit/s).
By brand
All 30Hikrobot 15Basler 9iRAYPLE 4Opto Engineering 2