The Hikrobot MV-CU200-20GC is a 20 MP color area scan camera built on an AR2020 CMOS sensor. The sensor is listed at 1/1.8" with 1.4 μm × 1.4 μm pixels and a 5120 × 3840 px array. The listed frame rate of 5.9 fps applies at 5120 × 3840 px in Bayer GR 8, which means the full-array output is raw Bayer data and color conversion is performed by the software or host that receives the image. That makes the model a fit for pipelines built to handle color processing, and for systems that need full-array resolution from a compact sensor format.
The shutter is CMOS with a rolling shutter, so rows are exposed in sequence and moving parts can show skew; the model suits static or slow-moving parts. The small 1.4 μm pixel pitch on a 1/1.8" format asks more of the optics and lighting. The lens must resolve the fine detail the array can record, and the illumination must supply enough light and uniformity that the fine pitch does not reduce signal quality across the frame.
Connectivity is GigE with GigE Vision V2.0 and GenICam support. Power is 9 VDC to 24 VDC, and PoE is listed as optional. The camera uses a C-mount, draws 2 W, and weighs 100 g. The IP30 rating applies under proper lens installation and wiring, so the camera should be housed in a protected enclosure rather than left exposed on the line.
Best for
Full-resolution color capture for software pipelines that perform color conversion from Bayer data
Wide-field color inspection of printed packaging or electronic assemblies on static parts
Dimensional imaging of mid-size parts across a 5120 × 3840 px array
GigE inspection installations in enclosed housings
Selection notes
The 5.9 fps figure applies at Bayer GR 8, so match the pixel format to what your software expects. Raw Bayer output needs color conversion downstream before an RGB image is available.
Install the camera in a protected enclosure. IP30 gives protection against solid objects and no protection against water, and it applies under proper lens installation and wiring.
Choose a lens that covers the 1/1.8" format and resolves the 1.4 μm pixel pitch across the full 5120 × 3840 px array.
Decide on the power path before the cabling is fixed: the baseline is 9 VDC to 24 VDC, and PoE is listed as optional.
Use bright, uniform lighting so the fine pixel pitch is well exposed, and keep exposures short when parts move because of the rolling shutter.
Specifications: General
Brand
Hikrobot
Camera type
Area scan
Specifications: Sensor
Shutter
CMOS, rolling shutter
Sensor model
AR2020
Sensor size
1/1.8"
Pixel size
1.4 μm × 1.4 μm
Resolution
20 MP
Horizontal resolution
5120 × 3840 px
Mono / color
Color
Specifications: Performance
FPS
5.9 fps @ 5120 × 3840 Bayer GR 8
Specifications: Interface
Interface
GigE
Protocols
GigE Vision V2.0, GenICam
Specifications: Optics
Mount
C-mount
Specifications: Electrical
Power
9 VDC to 24 VDC; PoE is optional
Power consumption
2 W
Specifications: Environment
IP rating
IP30 (under proper lens installation and wiring)
Specifications: Mechanical
Weight
100 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
30 frame grabbers / interface cards are compatible with this camera.
Matched automatically by: card supports the camera interface (gige vision) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this camera: GigE.