Skip to content
Hikrobot MV-CH120-90Y1M-NH machine vision camera
  • Rosepetal compatible
  • Recommended by AIS Vision

Hikrobot MV-CH120-90Y1M-NH

MV-CH120-90Y1M-NH

Hikrobot MV-CH120-90Y1M-NH — Gpixel GMAX3412 sensor, global shutter, 12 MP, 4096 × 3072 px, up to 93.9 fps, CoaXPress, C-mount mount.

Brand
Hikrobot
Camera type
Area scan
Shutter
CMOS, global shutter
Sensor model
Gpixel GMAX3412
Sensor manufacturer
Gpixel GMAX3412
Sensor size
1.1"
Pixel size
3.4 μm × 3.4 μm
Resolution
12 MP
Horizontal resolution
4096 × 3072 px
FPS
93.9 fps @ 4096 × 3072 Mono 8
Mono / color
Mono
Interface
CoaXPress

Technical overview

The Hikrobot MV-CH120-90Y1M-NH is a monochrome area scan camera with the Gpixel GMAX3412 CMOS sensor and a global shutter. The sensor is 1.1" in size with 3.4 μm × 3.4 μm pixels and resolves 12 MP at 4096 × 3072 px. Mono 8 output carries one 8-bit grey value per pixel, so the full sensor resolution is available directly for grey-level measurement, edge location and defect contrast. The global shutter exposes the whole frame at once, which keeps moving parts sharp and their geometry consistent.

The camera is rated at 93.9 fps at full resolution in Mono 8. That makes it a fit for production lines that need full-field monochrome frames at a fast cadence, such as surface inspection of moving parts, precise gauging and high-resolution label reading. The interface is CoaXPress in a 1-link CXP-12 configuration, with CoaXPress and GenlCam protocols. A single CXP link keeps the cabling to one connection between camera and frame grabber.

Power is 12 VDC to 24 VDC with PoCXP support, and consumption is 5 W at 170 g. The camera is configured with a heat sink and without a fan, so passive cooling through the heat sink is the thermal approach, and the mounting orientation and clearance around it matter. The C-mount takes standard C-mount optics, and the IP40 rating applies under proper lens installation and wiring. Since the output is monochrome, illumination should be designed for contrast on the target rather than for color.

Best for

  • Surface defect detection at 12 MP on fast-moving production lines.
  • Precise gauging and edge location with C-mount optics, where grey-level contrast carries the measurement.
  • High-resolution label and code reading across a wide field at full 4096 × 3072 px.
  • Single-link CoaXPress installations that favor one CXP-12 connection per camera.
  • Installations where a passive heat sink, rather than a fan, handles the thermal load.

Selection notes

  • Confirm the grabber supports a single CXP-12 link and the 93.9 fps rate at 4096 × 3072 px in Mono 8.
  • Keep the heat sink unobstructed and plan mounting orientation and enclosure airflow for the 5 W load, since there is no fan.
  • Use the PoCXP support deliberately: the camera takes 12 VDC to 24 VDC, and if the grabber supplies power over the cable, verify that before sizing a separate supply.
  • Pick a C-mount lens whose image circle covers the 1.1" sensor and whose resolution suits 3.4 μm pixels, so the 12 MP field is used.
  • Design the lighting for monochrome contrast on the target. If illumination must be synchronized with exposure, check trigger and I/O details in the manufacturer datasheet.

Specifications: General
BrandHikrobot
Camera typeArea scan

Specifications: Sensor
ShutterCMOS, global shutter
Sensor modelGpixel GMAX3412
Sensor manufacturerGpixel GMAX3412
Sensor size1.1"
Pixel size3.4 μm × 3.4 μm
Resolution12 MP
Horizontal resolution4096 × 3072 px
Mono / colorMono

Specifications: Performance
FPS93.9 fps @ 4096 × 3072 Mono 8

Specifications: Interface
InterfaceCoaXPress
ProtocolsCoaXPress, GenlCam

Specifications: Optics
MountC-mount

Specifications: Electrical
Power12 VDC to 24 VDC, supports PoCXP
Power consumption5 W

Specifications: Environment
IP ratingIP40 (under proper lens installation and wiring)

Specifications: Mechanical
Weight170 g

Frequently asked questions

Related technical guides

Often used with

Ring lights

A common starting point for area scan inspection. The right geometry depends on the surface.

All ring lights →
  • Basler Standard Light Ring-70OD-x (White / Red / Blue / IR) machine vision lighting
    BaslerBasler Standard Light Ring-70OD-xStandard Light Ring-70OD-x
    • Ring light (bright field)
    • White (also available Red 625 nm, Blue 465 nm, IR 850 nm)
    • Light-emitting ring surface 53-72 mm
    • Continuous and strobe (overdrive via SLP Strobe Controller)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Lumher RD1-5000K machine vision lighting
    LumherLumher RD1 White 5000KRD1-5000K
    • Ring
    • White 5000K
    • Continuous (1x) / Strobe (4x)
    • Semidiffuse 110° / Ultradiffuse 110°
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

CoaXPress cables

Industrial CoaXPress cables with locking connectors. Check length and flex rating against your installation.

All cables →
  • iRAYPLE AX0127MP1E-000 machine vision camera
    iRAYPLEiRAYPLE AX0127MP1E-000AX0127MP1E-000
    • Area Scan
    • CXP-12
    • 12 MP
    • Global
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Hikrobot MV-CH120-90X2M-C-NN machine vision camera
    HikrobotHikrobot MV-CH120-90X2M-C-NNMV-CH120-90X2M-C-NN
    • Area scan
    • CoaXPress
    • 12 MP
    • CMOS, global shutter
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Hikrobot MV-CH120-90Y1M-NN machine vision camera
    HikrobotHikrobot MV-CH120-90Y1M-NNMV-CH120-90Y1M-NN
    • Area scan
    • CoaXPress
    • 12 MP
    • CMOS, global shutter
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.