Skip to content
Hikrobot MV-CH250-90Y1C-NN machine vision camera
  • Rosepetal compatible
  • Recommended by AIS Vision

Hikrobot MV-CH250-90Y1C-NN

MV-CH250-90Y1C-NN

Hikrobot MV-CH250-90Y1C-NN — Gpixel GMAX0505 sensor, global shutter, 25 MP, 5120 × 5120 px, up to 41.3 fps, CoaXPress, C-mount mount.

Brand
Hikrobot
Camera type
Area scan
Shutter
CMOS, global shutter
Sensor model
Gpixel GMAX0505
Sensor manufacturer
Gpixel GMAX0505
Sensor size
1.1"
Pixel size
2.5 μm × 2.5 μm
Resolution
25 MP
Horizontal resolution
5120 × 5120 px
FPS
41.3 fps @ 5120 × 5120 Bayer BG 8
Mono / color
Color
Interface
CoaXPress

Technical overview

The Hikrobot MV-CH250-90Y1C-NN is a color area scan camera built on the Gpixel GMAX0505 CMOS sensor. The listed sensor size is 1.1", with 2.5 μm × 2.5 μm pixels and 25 MP resolution at 5120 × 5120 px. The sensor uses a global shutter, so every pixel in a frame is exposed at the same time, which keeps moving parts from skewing in the image. The listed frame rate is 41.3 fps at 5120 × 5120 px in Bayer BG 8, so the camera suits high-resolution color inspection that needs full-frame images at that rate.

The interface is CoaXPress, specified as 1-link CXP-12. The power input is 9 VDC to 24 VDC and the camera supports PoCXP (power over CoaXPress), so it can be powered over the coax link when the frame grabber supports it. The C-mount accepts standard C-mount lenses; choose one whose image circle covers the 1.1" sensor and whose focal length and working distance give the required field of view. The protocols are listed as GigE Vision V2.0 and GenlCam. Power consumption is 3.9 W and the weight is 74.5 g.

This configuration is built without fan and without heat sink, so the enclosure's thermal design deserves attention at the listed 41.3 fps. The IP40 rating applies under proper lens installation and wiring, which makes the lens mount and cable connections part of the protection concept. Taken together, the 25 MP global-shutter sensor, CoaXPress cabling and C-mount optics set the requirements for lighting, trigger timing and host hardware in the system design.

Best for

  • Full-resolution color inspection where the 5120 × 5120 px frame is needed to resolve fine detail across a large field of view.
  • Inspection of fast-moving products, where the global shutter avoids motion distortion in each frame.
  • Color-dependent verification tasks where Bayer BG 8 output at 41.3 fps fits the task.
  • CoaXPress-based systems that want power delivered over the same cable through PoCXP.
  • Wide-area imaging with C-mount lenses, where the 25 MP sensor keeps pixel-level detail across the whole frame.

Selection notes

  • Pair the camera with a CoaXPress frame grabber that matches the 1-link CXP-12 interface, and confirm the grabber supports PoCXP if you plan to power the camera over the cable.
  • Plan lighting and exposure around the 41.3 fps frame period; at this resolution and rate, short exposures still need enough light for usable image quality.
  • Because the configuration is built without fan and without heat sink, design the enclosure airflow with the 3.9 W power consumption in mind.
  • Select a C-mount lens whose image circle covers the 1.1" sensor and whose focal length sets the field of view at your working distance, and check that the sampling matches the 2.5 μm pixel pitch for your required feature size.
  • Check the trigger and I/O pinout in the manufacturer datasheet before wiring strobes and host inputs.

Specifications: General
BrandHikrobot
Camera typeArea scan

Specifications: Sensor
ShutterCMOS, global shutter
Sensor modelGpixel GMAX0505
Sensor manufacturerGpixel GMAX0505
Sensor size1.1"
Pixel size2.5 μm × 2.5 μm
Resolution25 MP
Horizontal resolution5120 × 5120 px
Mono / colorColor

Specifications: Performance
FPS41.3 fps @ 5120 × 5120 Bayer BG 8

Specifications: Interface
InterfaceCoaXPress
ProtocolsGigE Vision V2.0, GenlCam

Specifications: Optics
MountC-mount

Specifications: Electrical
Power9 VDC to 24 VDC, supports PoCXP
Power consumption3.9 W

Specifications: Environment
IP ratingIP40 (under proper lens installation and wiring)

Specifications: Mechanical
Weight74.5 g

Frequently asked questions

Related technical guides

Often used with

Ring lights

A common starting point for area scan inspection. The right geometry depends on the surface.

All ring lights →
  • Basler Standard Light Ring-70OD-x (White / Red / Blue / IR) machine vision lighting
    BaslerBasler Standard Light Ring-70OD-xStandard Light Ring-70OD-x
    • Ring light (bright field)
    • White (also available Red 625 nm, Blue 465 nm, IR 850 nm)
    • Light-emitting ring surface 53-72 mm
    • Continuous and strobe (overdrive via SLP Strobe Controller)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Lumher RD1-5000K machine vision lighting
    LumherLumher RD1 White 5000KRD1-5000K
    • Ring
    • White 5000K
    • Continuous (1x) / Strobe (4x)
    • Semidiffuse 110° / Ultradiffuse 110°
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

CoaXPress cables

Industrial CoaXPress cables with locking connectors. Check length and flex rating against your installation.

All cables →

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.